
BTune delivers a 20% whole building energy reduction on average for our customers.
120 N. LaSalle
Chicago, Illinois
Located in the heart of downtown Chicago, 120 North LaSalle is a LEED-Gold certified building with on-site management and engineering staff. Lincoln Property Company engaged BTune to improve energy performance to achieve a higher building rating while reduce operating costs, improving comfort, reducing equipment wear-and-tear, and streamlining maintenance management.
Energy & Carbon
13.1%
Whole Building
Energy Reduction
12.5%
Reduction in
Total Energy Bill
10.3%
Average Peak
Demand Reduction
13 t
Carbon Emissions
Reduction
Maintenance & Comfort
36%
Reduction in Monthly Fan Runtime
(14,715 hours)
10.3%
Reduction in Monthly VAV Electric Reheat Time
(10,465 hours)

“BTune is the first technology we’ve used that really works. And unlike other options that suggested equipment replacement, paying for new programing changes or hours of our time, BTune has been so easy to implement–we just plugged in the box and they could implement the changes on their own. They really understand our building and ensure it’s controlled the way we need it to be, rather than fitting it into their own prescribed rules.”
Bob Mielnicki
Building Engineer, 120 N. LaSalle
Lincoln Property Company

20 Customhouse Quay
Wellington, New Zealand
Managed by Stride Property Group, this 13-story prime office building is located in the heart of Wellington City. With 17,500 sqm of lettable area, it is home to various high-profile tenants, including Deloitte, Chapman Tripp, NZI, Kiwibank, and others. The building has a 5-star Green Star Office Design rating.
18%
Average Monthly Base Building Energy Reduction
12.5%
Reduction in
Total Energy Bill
20 t
Carbon Emissions
Reduction
Lago Alberto 365
Mexico City, Mexico
Lago Alberto 365 is a 21-story Class-A high-rise office in Mexico City. BTune was deployed across the central plant to not only reduce energy consumption, but also peak demand charges to lower costs while maintaining comfort. The demand reduction occurred via BTune deploying an automated optimized Turn Down and Stop for HVAC equipment after 5pm.​
13%
Reduction in Whole
Building Energy Use
18%
Reduction in
Total Energy Bill
49%
Reduction During Peak Demand Period
16%
Reduction In
Carbon Emissions

“After months of helping our customers automate their energy management to unlock significant savings, we found BTune. Following many iterations of our own product, BTune has proven to be the simplest and most effective way to deliver real, measurable savings for our customers."
Alvaro Migoya
Co-Founder & CEO
Batu Energy

SkyCity
Auckland, New Zealand
SkyCity is a premier entertainment complex located in the heart of Auckland’s Central Business District. SkyCity is a premier entertainment complex (~1.5 million sqf) located in the heart of Auckland’s Central Business District. BTune was engaged to help the SkyCity Entertainment Complex achieve its energy consumption target by optimizing HVAC energy use in the hotel and casino facilities. Along with reducing energy use and costs, BTune was also leveraged to decrease carbon emissions.
20%
Whole Building
Energy Reduction
$610,000
Energy Cost Savings
1,233
Ton Carbon Emissions
Reduction
BTune’s technology quickly analyzed the entire HVAC system to identify areas of inefficient operation and provided a recommended Energy Conservation Measure (ECM) to align the system with best practice performance. Some of these ECMs included:
​
-
Reduce the HHW flow temperature and pumping energy
-
Increase CHW flow temperature setpoint
-
Adjust the temperature and relative humidity setpoints and deadbands
-
Override the dew point control operation on Casino AHUs
-
Adjusted supply air temperatures on all AHUs
-
Reduced the fan speeds via VSD or EC fan controllers on all AHUs and FCUs
-
Implemented a proportional only Demand Control Ventilation (DCV) strategy with outdoor air dampers control
KIPP DC Public Schools
Washington, D.C.
The campus building on Benning Road houses early education, elementary and middle schools comprising roughly 110,000sqft of space. BTune was engaged to optimize HVAC energy performance to reduce energy costs and carbon emissions.
18%
Average Monthly Base Building Energy Reduction
12.5%
Reduction in
Total Energy Bill
20
Ton Carbon
Emissions Reduction

“Reducing energy costs not only improves our environmental performance, but it also means more money reinvested into classrooms–a real win-win supporting the education sectors long-term mission.”
Terry Herr
President
Intellimation